FARM Series
The whole machine adopts high protection design, can work in the harsh environment
All load-bearing parts are made of 304 stainless steel
Related products
Natural gas supply method is divided into Dewar tank gas supply, one body skid gas supply, standard station gas supply, gas supply.
LPG supply methods are divided into cylinder gas supply, centralized gas supply in cylinder sets, containerized centralized gas supply, and large storage tank gas supply.
Material and protection
The whole machine adopts high protection design, can work in harsh environment
All load-bearing parts are made of 304 stainless steel
The panel is designed to strengthen the structure and can be installed horizontally or vertically
All structural parts are connected with independent fasteners to enhance the strength of the equipment
Operation and maintenance
Independent modularization of each unit, simple disassembly, easy cleaning and maintenance
Anti-misassembly design, easy installation to change fuel type for the equipment
Safety protection
Pre-heating and post-cooling mode, constant temperature output, soft air supply without stress
Multiple overheating protection for the whole machine design, combustion safety monitoring
Functional advantages
Equipped with high pressure fan, in line with ERP2015 high standard specification
Low wind noise in operation (less than 69 db in one meter range)
Adopt 7-side fan blade to make the best effect of air flow and static pressure
Support a variety of control connections, temperature / humidity, time controller, ring control command
Adopt multi-circulation heat exchange structure, thermal efficiency up to 93% or more
Combustion from outdoor air, flue gas exhaust to outdoor, suitable for large heating places with high environmental requirements
Model |
FARM85M * |
FARM110M * |
FARM145M * |
FARM185T * |
FARM235T * |
|
Rated power | [kW] | 85,62 | 110,46 | 144,72 | 185,54 | 235,72 |
Heat output power | [kW] | 79,37 | 102,51 | 45,23 | 85,36 | 216,86 |
Thermal efficiency | [ % ] | 92,70 | 92,80 | 93,20 | 90,20 | 90,20 |
Air volume | [ m²/h ] | 7000 | 8500 | 11000 | 12000 | 16200 |
Static pressure | [ Pa- mm H2O ] | 200-20 | 200-20 | 200-20 | 200-20 | 200-20 |
Temperature rise | a 20°C [ °C ] | 48 | 52 | 52 | 61 | 58 |
Effective heating range | [ m ] | 45 | 43 | 43 | 51 | 55 |
Oil consumption | [ kg/h ] | 6,77 | 8,74 | 11,45 | 14,68 | 18,65 |
Natural gas energy consumption | [ m²/h ] | 7,935 | 10,433 | 13,664 | 17,383 | 22,095 |
Natural gas input pressure | [ mbar ] | 20 | 20 | 20 | 20 | 20 |
Liquefied gas energy consumption | [ m²/h - kg/h ] | 3,127-6,120 | 4,191-8,07 | 5,436-10,53 | 6,976-13,59 | 8,819-17,17 |
Liquefied gas input pressure | [ mbar ] | 30/37 | 30/37 | 30/37 | 30/37 | 30/37 |
Electricity parameters | [ V - ph - Hz ] | 230-1-50 | 230-1-50 | 230-1-50 | 400-3-50 | 400-3-50 |
Electricity consumption | [W] | 670 | 1190 | 1570 | 1550 | 2500 |
Size | [mm] | 980*910*738 | 1110*950*768 | 1220*1080*838 | 1324*1140*858 | 1514*1310*938 |